Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
Clin. transl. oncol. (Print) ; 26(2): 456-460, feb. 2024.
Artigo em Inglês | IBECS | ID: ibc-230190

RESUMO

Purpose Brachytherapy (BT) has been used for many years for disease control in tumours of the head and neck area (H&N). It is currently performed with high dose rate (HDR) or pulsed dose rate (PDR), but its use has been reduced due to the implementation of new non-invasive external beam radiotherapy techniques such as intensity modulation (IMRT) and volumetric modulated arc therapy (VMAT) and the improvement of surgical techniques. Methods The Spanish Brachytherapy Group (GEB) has carried out a survey to find out the number of centres in Spain that continue to use BT in H&N and its indications and expectations for the future. Results The results were presented at the XX GEB Consensus Meeting held on October 21, 2022, in Valencia (Spain) and it was confirmed that, although there are fewer and fewer centres that use BT in H&N, there are still units with extensive experience in this technique that should be positioned as referral centres. Conclusion It is necessary to carry out continuous work with other specialities involved, such as H&N surgeons, and other radiation oncologists, to improve the training of residents, both oncologists and medical physicists (AU)


Assuntos
Humanos , Braquiterapia/métodos , Planejamento da Radioterapia Assistida por Computador , Radioterapia de Intensidade Modulada/métodos , Neoplasias de Cabeça e Pescoço/radioterapia , Fracionamento da Dose de Radiação , Espanha
2.
Clin Transl Oncol ; 26(2): 456-460, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37548869

RESUMO

PURPOSE: Brachytherapy (BT) has been used for many years for disease control in tumours of the head and neck area (H&N). It is currently performed with high dose rate (HDR) or pulsed dose rate (PDR), but its use has been reduced due to the implementation of new non-invasive external beam radiotherapy techniques such as intensity modulation (IMRT) and volumetric modulated arc therapy (VMAT) and the improvement of surgical techniques. METHODS: The Spanish Brachytherapy Group (GEB) has carried out a survey to find out the number of centres in Spain that continue to use BT in H&N and its indications and expectations for the future. RESULTS: The results were presented at the XX GEB Consensus Meeting held on October 21, 2022, in Valencia (Spain) and it was confirmed that, although there are fewer and fewer centres that use BT in H&N, there are still units with extensive experience in this technique that should be positioned as referral centres. CONCLUSION: It is necessary to carry out continuous work with other specialities involved, such as H&N surgeons, and other radiation oncologists, to improve the training of residents, both oncologists and medical physicists.


Assuntos
Braquiterapia , Radioterapia de Intensidade Modulada , Humanos , Braquiterapia/métodos , Espanha , Radioterapia de Intensidade Modulada/métodos , Pescoço , Planejamento da Radioterapia Assistida por Computador/métodos , Dosagem Radioterapêutica
3.
Cancers (Basel) ; 14(14)2022 Jul 17.
Artigo em Inglês | MEDLINE | ID: mdl-35884528

RESUMO

Intracavitary brachytherapy (BT, Interventional Radiotherapy, IRT), plays an essential role in the curative intent of locally advanced cervical cancer, for which the conventional approach involves external beam radiotherapy with concurrent chemotherapy followed by BT. This work aims to review the different methodologies used by commercially available treatment planning systems (TPSs) in exclusive magnetic resonance imaging-based (MRI) cervix BT with interstitial component treatments. Practical aspects and improvements to be implemented into the TPSs are discussed. This review is based on the clinical expertise of a group of radiation oncologists and medical physicists and on interactive demos provided by the software manufacturers. The TPS versions considered include all the new tools currently in development for future commercial releases. The specialists from the supplier companies were asked to propose solutions to some of the challenges often encountered in a clinical environment through a questionnaire. The results include not only such answers but also comments by the authors that, in their opinion, could help solve the challenges covered in these questions. This study summarizes the possibilities offered nowadays by commercial TPSs, highlighting the absence of some useful tools that would notably improve the planning of MR-based interstitial component cervix brachytherapy.

4.
J Contemp Brachytherapy ; 13(6): 680-686, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-35079255

RESUMO

PURPOSE: The aim of this paper was to assess development of high-dose-rate (HDR) cervix brachytherapy (BT) implants in three Spanish institutions before and after introduction of EMBRACE II protocol. MATERIAL AND METHODS: 392 patients from three different institutions, treated between 2009 and 2019 were analyzed. D90 of high-risk clinical target volume (HR-CTV) and D2cc of organs at risk (OARs) of all patients were collected. Statistical distribution was analyzed for two different periods of time: before and after EMBRACE II publication. Index I was applied based on collected dosimetric quantities (D90 and D2cc) to enhance equilibrium between HR-CTV coverage and doses to OARs. Variation in dosimetry and index depending on CTV and technique used (IC vs. IC/IT) were also evaluated. RESULTS: Adaptation of institutions to EMBRACE II protocol resulted in a statistically significant increase of D90 HR-CTV (Institution 1; p < 0.00001) or decrease of D2cc OARs (Institution 2; p < 0.04). Increase in the use of interstitial component showed higher coverage of HR-CTV for Institution 3 (p = 0.03), and lower doses to OARs for the same coverage of HR-CTV at Institution 2 (p-OARs < 0.03). Even though index I was only significantly different between periods for Institution 1 (p < 0.0000001), it was able to show a reduction of dose variability related to higher expertise and higher interstitial component. CONCLUSIONS: Depending on local protocol before EMBRACE II, the adaptation through increasing interstitial component and physician and physicist training, resulted in a significant increase of HR-CTV doses or reduction of OARs doses. Index I was able to describe an evolution of equilibrium between CTV coverage and OARs' sparing.

5.
Phys Med Biol ; 62(23): 9099-9111, 2017 Nov 14.
Artigo em Inglês | MEDLINE | ID: mdl-29057748

RESUMO

Dosimetry in liver radioembolization with 90Y microspheres is a fundamental tool, both for the optimization of each treatment and for improving knowledge of the treatment effects in the tissues. Different options are available for estimating the administered activity and the tumor/organ dose, among them the so-called partition method. The key factor in the partition method is the tumor/normal tissue activity uptake ratio (T/N), which is obtained by a single-photon emission computed tomography (SPECT) scan during a pre-treatment simulation. The less clear the distinction between healthy and tumor parenchyma within the liver, the more difficult it becomes to estimate the T/N ratio; therefore the use of the method is limited. This study presents a methodology to calculate the T/N ratio using global information from the SPECT. The T/N ratio is estimated by establishing uptake thresholds consistent with previously performed volumetry. This dose calculation method was validated against 3D voxel dosimetry, and was also compared with the standard partition method based on freehand regions of interest (ROI) outlining on SPECT slices. Both comparisons were done on a sample of 20 actual cases of hepatocellular carcinoma treated with resin microspheres. The proposed method and the voxel dosimetry method yield similar results, while the ROI-based method tends to over-estimate the dose to normal tissues. In addition, the variability associated with the ROI-based method is more extreme than the other methods. The proposed method is simpler than either the ROI or voxel dosimetry approaches and avoids the subjectivity associated with the manual selection of regions.


Assuntos
Embolização Terapêutica , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/radioterapia , Microesferas , Agregado de Albumina Marcado com Tecnécio Tc 99m , Tomografia Computadorizada de Emissão de Fóton Único , Radioisótopos de Ítrio/uso terapêutico , Humanos , Radiometria , Radioisótopos de Ítrio/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...